Parallel caps share ripple current by ESR - mismatched parts age unevenly; use same batches and equal traces.
Series caps divide voltage by leakage resistance - balancing resistors (current ≥10× leakage) or active balancers are mandatory.
Bleeder sizing example: 450V unit, 1mA leakage → ≤45kΩ per stage; budget its continuous power dissipation.
| Config | Root cause | Symptom | Countermeasure |
|---|---|---|---|
| Parallel | ESR spread | Ripple偏载 | Same batch, equal traces |
| Series | Leakage spread | Overvoltage | Balancing resistors |
| Series (ripple) | C differences | AC misdivision | Matched values |
| Supercap series | Large leakage | Tight balancing | Active board |
| Electrolytic parallel | Thermal coupling | Neighbour aging | Spacing |
| Mixed series | Small C | Highest voltage | Forbidden |
Apply the points above to Capacitor banks; the figures are typical engineering values, so confirm them against the device datasheet and the actual design before release.
The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Per IEC 61071, IEC 62391 and the corresponding IEC documents. Ratings and derating follow the device datasheet and the product design file. Always check the device datasheet and the product design file for ratings and derating.
Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.