RC snubbers for SCRs and IGBTs

SCRs false-fire on fast anode dv/dt - an RC across A-K keeps it below the rated limit.

1. How it works

IGBT turn-off spikes come from stray inductance: snubbers absorb the excess, but low-inductance busbars and decoupling caps are the root cure.

2. Practice and pitfalls

Resistor power = switching energy × frequency; verify with ring-convergence and resistor temperature on the real build.

3. Snubber table

TargetTypical configGoalLoss scale
SCRRC 0.1~1μFdv/dt immunityWatts
Small IGBTRC / decouplingTurn-off spikeFew watts
Large IGBTRCD clampOvervoltage clampTens of watts
Rectifier inputRC+MOVSurge, dv/dtWatts
MOSFET half-bridgeDecoupling capsHot loop—
VFD outputdu/dt filterMotor insulationPer motor

4. Notes

Apply the points above to RC snubbers for SCRs and IGBTs; the figures are typical engineering values, so confirm them against the device datasheet and the actual design before release.

5. References

The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Per GB/T 15291 and the corresponding IEC documents. Ratings and derating follow the device datasheet and the product design file. Always check the device datasheet and the product design file for ratings and derating.

6. Cautions

⚠️ Three common pitfalls:
① Rating snubber resistors by average current
② Snubbers instead of layout fixes
③ Leaded parts in snubber positions

Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.

Related reading

Related 3D models: Ready to build it? Download free 3D models & CAD drawings at MOULDL »