Handling AC with phasors and complex numbers is far easier than solving differential equations. This page introduces writing sines as complex phasors and using impedance so series and parallel circuits compute like DC.
A sine u equals U peak sine of omega t plus phi becomes the phasor U at angle phi, where the length is the RMS and the angle is the initial phase; the shared time factor e to j omega t is dropped. Differentiation then becomes multiply by j omega, so circuit equations turn algebraic.
Impedance in complex form is R for a resistor, j omega L for an inductor and one over j omega C for a capacitor. Total Z is R plus j of XL minus XC, with magnitude root of R squared plus X squared and angle atan of X over R. Current phasor I equals U over Z, and the phase between voltage and current is that angle.
| Part | Impedance | Nature |
|---|---|---|
| Resistor | R | real |
| Inductor | j w L | positive imag |
| Capacitor | 1/(j w C) | negative imag |
| Series | add | Z = sum Zk |
| Parallel | reciprocal | 1/Z = sum 1/Zk |
| Magnitude | root R2+X2 | total Z |
Phasors are the key to进阶. Most loads are inductive, so remember inductor gives positive imaginary and capacitor negative; a positive net imaginary means inductive. At resonance the imaginary parts cancel, so avoid the resonant point near the working frequency.
The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Circuit analysis follows GB/T 2900 and power quality GB/T 14549. Always check the device datasheet and the product design file for ratings and derating.
Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.