An enclosure that survives a dry workshop dies in a washdown bay within a season. This page maps IP code digits to environments, adds the corrosion dimension that IP ignores, and notes where high IP actually hurts.
The first IP digit covers solids and the second water: IP2X fingers, IP4X tools and wires, IP5X dust protected, IP6X dust tight; for water, IPX3 spray, IPX4 splashing, IPX5 hose jets, IPX6 heavy seas, IPX7 immersion, IPX8 continuous. Dry indoor panels live at IP20 to IP32, damp workshops want IP54 to IP55, outdoor and washdown areas need IP65, and submerged or hosed equipment demands IP67.
IP says nothing about chemistry: in pickling lines and coastal plants the second selection axis is the corrosion class, WF1 to WF3 for outdoor pollution and material choice such as 316 stainless or glass reinforced polyester enclosures. Beware the paradox that sealing too well traps moisture inside: a temperature swing condenses water on the inside of an IP65 cabinet, so add drains, breathers or a small anti condensation heater. Cable glands must match the rating too, since an IP65 box fed through unrated glands is effectively IP44.
| Environment | Recommended IP | Additional requirement |
|---|---|---|
| Dry indoor | IP20 to IP32 | None |
| Damp workshop | IP54 to IP55 | Anti condensation care |
| Outdoor with rain | IP65 | Corrosion class check |
| Acid and pickling lines | IP65 with 316 steel | Chemical resistant material |
| Washdown or immersion | IP67 | Sealed glands |
| Dusty explosive areas | IP6X with Ex marking | Explosion proof housing |
Match IP to the wettest realistic condition, add corrosion class and material separately, and never forget that glands and doors carry the rating, not the sheet metal.
The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Enclosure protection degrees are defined in GB/T 4208, identical to IEC 60529, with corrosion environments per GB/T 5226.1 and IEC 60204-1. Always check the device datasheet and the product design file for ratings and derating.
Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.