Phase difference, phase angle and drawing the phasor diagram

Which of two same-frequency sines leads is told by the phase difference. This page shows how to compute it, how to draw the phasor diagram, and why that angle drives sequence and power factor checks.

1. How it works

For two sines at the same frequency, the phase difference delta phi equals phi one minus phi two. Positive means the first leads, negative means it lags. The idea only exists for equal frequencies; different frequencies have no fixed phase. A resistor is in phase, an inductor current lags by 90 degrees, a capacitor leads by 90.

2. Practice and pitfalls

From the waveform, delta phi equals 360 times delta t over T. At 50 Hz with a 5 millisecond shift the angle is 90 degrees. Use a two-channel scope triggered on both and measure the zero-crossing gap, keeping probe delays matched. Draw phasors as vectors of length equal to RMS at the initial angle, with the supply as the reference pointing right.

3. Phase relationships

LoadCurrent vs voltageAngle
Resistorin phase0
Inductorlags-90
Capacitorleads+90
Inductivelags0 to -90
Capacitiveleads0 to 90
3-phase120 apart120

4. Notes

Draw a phasor sketch before checking sequence, power factor or resonance; it is faster than algebra. Match probe delays and use identical probes so instrument error never enters the angle you read.

5. References

The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Electrical terms follow GB/T 2900 and measurement IEC 60051. Always check the device datasheet and the product design file for ratings and derating.

6. Cautions

⚠️ Three common pitfalls:
① Computing phase between different frequencies gives nonsense
② Unmatched probe delay injects instrument error into the angle
③ Wrong reference phasor rotates the whole diagram but still wrong

Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.

Related reading

Related 3D models: Ready to build it? Download free 3D models & CAD drawings at MOULDL »