Inductor energy storage and the freewheel loop in SMPS

Switch on: inductor stores LI²/2; switch off: current freewheels through diode or synchronous rectifier to the load.

1. How it works

Two iron rules: keep the hot loop small, use fast diodes / low-RDS(on) FETs.

2. Practice and pitfalls

Ripple current 20~40% of output sets L; verify no saturation at peak with a current probe.

3. SMPS parameters

ParameterFormula/valueRoleWatch
Ripple ΔI0.2~0.4 IoutSets LLosses
InductanceU·D·T/ΔIRipple controlIsat
Freewheel deviceSchottky/syncLoss cutReverse recovery
Hot loopMinimiseEMI/spikesLayout first
EnergyLI²/2TransportSaturation
DutyUout/UinRatioLimits

4. Notes

Apply the points above to Inductor energy storage and the freewheel loop in SMPS; the figures are typical engineering values, so confirm them against the device datasheet and the actual design before release.

5. References

The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Per GB 4943.1, GB/T 19826 and the corresponding IEC documents. Ratings and derating follow the device datasheet and the product design file. Always check the device datasheet and the product design file for ratings and derating.

6. Cautions

⚠️ Three common pitfalls:
① Ignoring saturation at peak current
② Slow rectifiers as freewheel diodes
③ Wide hot loops on the PCB

Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.