Both position, but one is cheap open-loop and the other precise yet costly. This page lays out torque, accuracy, speed and cost so you save where you can and spend where you must.
A stepper is open-loop with large low-to-mid speed torque, stable at low speed but collapsing torque at high speed, risk of lost steps and moderate accuracy from step angle. A servo is closed-loop with flat torque across speed, still strong at high speed, high accuracy from encoder feedback with correctable error, fast dynamics and no accumulated error, but complex, PID-tuned and several times the cost.
Cost: a stepper motor is tens to hundreds of yuan with a simple driver, no tuning, rugged; a servo motor plus drive costs multiples, needs commissioning, has a fragile encoder and higher maintenance. Power: a stepper holds current even unloaded, while a servo delivers on demand and saves energy. A stepper can lose steps unknowingly; a servo corrects in real time. Choose servo for high accuracy, high speed, varying load and no-step-loss duties like CNC and robots; choose stepper for mid-low speed, steady load, cost-sensitive, moderate-accuracy uses like simple feeds, valves and printers. Closed-loop steppers are a middle option with encoder feedback against lost steps. Weigh accuracy, speed and budget; do not over-serveo nor push a stepper to its limit.
| Item | Stepper | Servo | Verdict |
|---|---|---|---|
| Control | Open loop | Closed loop | Servo accurate |
| High-speed torque | Collapses | Flat | Servo wins |
| Accuracy | Medium | High | Servo wins |
| Cost | Low | Several times higher | Stepper wins |
| Commissioning | None | PID tuning | Stepper easier |
| Lost steps | Possible | None | Servo stable |
Steppers run open loop with strong mid-low speed torque, medium accuracy and no commissioning, but torque collapses at speed and steps can be lost. Servos run closed loop with flat torque across the range, high accuracy and no accumulated error, yet cost several times more and need PID tuning and upkeep. Choose: CNC, robots, high speed or variable load where a lost step is unacceptable, take a servo; steady mid-low speed duty on a budget, take a stepper; closed-loop steppers split the difference. Weigh precision, speed and budget together.
The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Electrical drives: GB/T 12668 / IEC 61800; safety: GB/T 5226.1. Always check the device datasheet and the product design file for ratings and derating.
Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.