Over current and over voltage protection design

The worst a failed supply can do is take the load with it, so current limit and over voltage clamp are the two life saving features. This page covers how they are built and set.

1. How it works

Over current usually uses a sense resistor and comparator: past threshold the comparator flips to limit or shut down. A linear supply can let the pass transistor enter constant current (foldback or constant limit), and a switcher cuts duty or hiccups. Set threshold at 1.2 to 1.5 times rated; too low false trips, too high burns the load. Hiccup protection self recovers when the fault clears, good for shorts.

2. Practice and pitfalls

Over voltage uses a zener plus TVS or a thyristor crowbar: above set point the zener fires the SCR which shorts output to ground and blows the fuse, stopping HV reaching the load. Sampling and comparison can also shut down. TVS is fast for transients. Set within load rating; too sensitive trips on normal ripple. The crowbar needs a matched fuse or the SCR dies.

3. Protection parameters

ProtectImplementThreshold
Over Isense and comprated 1.2 to 1.5
Const Ipass xstrfoldback
Over VTVS crowbarwithin load V
Hiccupauto recovershort ok
Fusewith crowbarcurrent match
Sense RI squared Rpower margin

4. Notes

Limit current at 1.2 to 1.5 times rated or hiccup, and clamp over voltage with TVS or thyristor plus fuse. Do not set the threshold too tight or too loose, rate the sense resistor by I squared R with margin, and actually test that the trip works; add self recovery to cut manual resets.

5. References

The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Supply protection per GB/T 5226.1; safety to IEC 60204-1 and GB/T 12350. Always check the device datasheet and the product design file for ratings and derating.

6. Cautions

⚠️ Three common pitfalls:
① Threshold too low trips at start surge, too high burns even on short.
② Crowbar thyristor under rated current blows; match the fuse.
③ Fitting protection yet never testing the trip means no protection at all.