A stepper moves in counted steps: give it pulses and it turns by steps. This page explains how phase sequencing steps the rotor, how step angle is computed, and why it positions without an encoder.
The stator has several phases; the controller energises them in sequence so the stator field axis jumps one step and the toothed rotor is pulled to that position by magnetic force. Each commutation advances one step angle, so the rotor moves discretely; speed equals pulse frequency times step angle and angle equals pulse count times step angle.
Step angle theta is 360 divided by phases times rotor teeth times mode coefficient, where mode is 1 for full step and 2 for half step. A 2-phase 50-tooth motor gives 3.6 degrees full step, 1.8 half step, and finer under microstepping. Because each step is fixed, total angle equals steps times step angle, so open-loop positioning works without feedback, as long as no steps are lost. The price is that overload or too-fast acceleration causes lost steps and position error, so steppers suit medium-low speed, steady loads and moderate accuracy.
| Phases | Teeth | Full step | Half step |
|---|---|---|---|
| 2 | 50 | 3.6 deg | 1.8 deg |
| 2 | 100 | 1.8 deg | 0.9 deg |
| 2 | 200 | 0.9 deg | 0.45 deg |
| 5 | 50 | 1.44 deg | 0.72 deg |
| 3 | 50 | 2.4 deg | 1.2 deg |
A stepper advances one step per commutation as magnetic pull snaps the rotor to the next aligned set of teeth, so angle equals pulses times step and speed equals frequency times step, which is why open-loop positioning works without an encoder. Step angle theta = 360/(m x z x k); a 2-phase 50-tooth motor takes 3.6 degrees per full step. The catch: overload or excessive speed loses steps, so steppers suit medium-low speed, steady loads.
The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Product standards for steppers apply; electrical safety: GB/T 5226.1 / IEC 60204-1. Always check the device datasheet and the product design file for ratings and derating.
Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.