Ohm's law in hands-on troubleshooting

Measure two of U, I, R and compute the third; the odd one out marks the fault.

1. How it works

Voltage-drop patrol: walk the loop and measure drops - any abnormal drop is the bad joint, R=ΔU/I.

2. Practice and pitfalls

Cross-check with physics: impossible numbers mean a wrong premise (AC/DC mix, sign error), not a miracle.

3. Symptom-to-derivation table

SymptomMeasureDerivePoints to
IntermittentPer-segment dropsSegment RBad joint
Current highI and UR=U/I smallWinding short
Current lowI and UR=U/I largeLoop resistance up
Far-end sagBoth endsLine dropUndersized wire
Weak heatingU²/RHot resistanceAged element
Relay won't pullCoil voltage<85%UnLoop drop

4. Notes

Apply the points above to Ohm's law in hands; the figures are typical engineering values, so confirm them against the device datasheet and the actual design before release.

5. References

The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Per GB/T 16895 and the corresponding IEC documents. Ratings and derating follow the device datasheet and the product design file. Always check the device datasheet and the product design file for ratings and derating.

6. Cautions

⚠️ Three common pitfalls:
① Concluding without re-measuring
② Applying DC reasoning to AC loops
③ Patrolling drops without logging load

Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.