The many divide modes of the asynchronous 74LS90 counter

One 74LS90 serves as divide-by-two, divide-by-five or divide-by-ten, which is why it is everywhere in legacy boards. This page shows the internal structure and the wiring for each ratio.

1. How it works

Internal structure: the 74LS90 contains an independent divide-by-two toggle stage, CP1 in and Q0 out, plus a divide-by-five Johnson section, CP2 in and Q1 to Q3 out. The two halves work alone or cascade. Supply is 5V TTL levels, and outputs can drive LEDs directly through current-limiting resistors.

2. Numbers and practice

Three divide wirings: divide by two, clock into CP1 and take Q0, one toggle every two beats. Divide by five, clock into CP2 and take Q3 out, the section walking 0 to 4. Divide by ten, link Q0 to CP2 and clock CP1, so the whole chip walks BCD 0 to 9 and divides by ten at once. Changing the wiring changes the ratio, one chip doing the work of three.

3. Pitfalls and fixes

Field notes: it is a ripple structure, so high bits lag; keep frequencies moderate, the raw limit is about 40MHz but inter-stage delay shows well before that. It suits clock division and mains shaping, 50Hz down to a second pulse. Decoding the Q outputs for a display needs a driver such as the 74LS47. The reset pins R0(1) and R0(2) force zero when both go high, and the set-to-9 pins preset that value.

4. 74LS90 divide wiring table

Divide ratioClock intoOutputCascade
2CP1Q0Standalone
5CP2Q3Standalone
10CP1Q0 to Q3Q0 into CP2
Divide by twoSingle stageOne toggleChainable
Divide by tenBCD walk0 to 9Common
ResetR0 pins highAll zeroClear

5. Notes

For divide by ten link Q0 to CP2 and change the wiring to change the ratio. The ripple structure limits speed, so move to a synchronous chip when fast.

6. References

The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Asynchronous division per GB/T 4728 and IEC 60617 symbols. Always check the device datasheet and the product design file for ratings and derating.

7. Cautions

⚠️ Three common pitfalls:
① Expecting divide by ten without linking Q0 to CP2:you get only divide by two and the ratio is wrong
② Ripple structure pushed past its speed:inter-stage delay misaligns the high bits
③ Reset pins left floating:the chip clears itself at power-up and never counts

Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.