Battery series vs parallel: voltage, capacity and internal resistance

Series multiplies voltage (n·E) and internal resistance (n·r) with unchanged Ah; parallel multiplies Ah and divides r.

1. How it works

Series needs cell balancing; parallel needs matched cells to avoid circulating currents.

2. Practice and pitfalls

Energy (Wh) depends only on cell count and type; never mix old and new cells in one string.

3. Combination table

ConfigVoltageCapacityRKey requirement
3S3E1×Ah3rBalancing
4P1×E4×Ahr/4Matched cells
3S4P3E4Ah3r/4BMS
Redundant pair1×ESameHalfIsolation diodes
Large mixedPer layoutPer layoutPer layoutBMS mandatory
Old+new———Forbidden

4. Notes

Apply the points above to Battery series vs parallel; the figures are typical engineering values, so confirm them against the device datasheet and the actual design before release.

5. References

The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Per GB 31241, GB/T 31485 and the corresponding IEC documents. Ratings and derating follow the device datasheet and the product design file. Always check the device datasheet and the product design file for ratings and derating.

6. Cautions

⚠️ Three common pitfalls:
① Stringing old and new cells together
② Paralleling unmatched cells
③ Charging series strings without balancing

Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.