Thermistor, varistor and photoresistor: three different jobs

NTC senses temperature and provides inrush soft-start; PTC protects against overcurrent and winding overheating.

1. How it works

MOV clamps surge energy across the line input - always upstream of a fuse since failure mode is a short.

2. Practice and pitfalls

CdS cells suit light switches, not measurement; phototransistors replace them in new designs.

3. Sensitive resistor comparison

TypeBehaviourTypical useFailure mode
NTCT↑ → R↓Inrush, sensingOpen/drift
PTCT↑ → R↑Overcurrent, motorWon't reset
MOVU↑ → R↓Surge clampShort + heat
CdS cellLight↑ → R↓Light switchAging drift
PhototransistorLight↑ → I↑Precision detectSaturation
Motor PTCWinding temp tripWinding protectionNuisance trips

4. Notes

Apply the points above to Thermistor, varistor and photoresistor; the figures are typical engineering values, so confirm them against the device datasheet and the actual design before release.

5. References

The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Per GB/T 6663, GB/T 10193, IEC 61051, GB 50057 and the corresponding IEC documents. Ratings and derating follow the device datasheet and the product design file. Always check the device datasheet and the product design file for ratings and derating.

6. Cautions

⚠️ Three common pitfalls:
① Fitting MOVs without upstream fuse
② Sizing NTC soft-start by resistance only - energy matters
③ Using CdS cells for precision measurement

Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.