How thick the enamel wire is in a motor winding is set by current density; too thin burns too thick will not fit the slot. This page explains current density value and slot fill.
Current density J equals rated current divided by total conductor cross section in A per mm2 and reflects heating. Small and medium motors commonly use 4 to 8 A per mm2 depending on cooling: closed fan cooled 4 to 5 open 6 to 8. Higher J packs more power but runs hotter.
To size wire first estimate phase current from power voltage efficiency and power factor then compute cross section S equals I divided by J and single wire diameter d equals square root of 4 S over pi times parallel count. Then check slot fill which should stay 70 to 75 percent for closed and up to 80 open; above 85 the wire will not fit and forcing it damages insulation. Pit: using thin wire to cut cost with J over 8 overheats; pit: too thick wire exceeds slot fill.
| Duty | Current density J | Slot fill | Note |
|---|---|---|---|
| Closed fan | 4 to 5 A/mm2 | 70 to 75% | poor cooling |
| Open | 6 to 8 A/mm2 | 75 to 80% | better cooling |
| Over J | above 8 | overheat | insulation ages |
| Over fill | above 85% | no fit | force breaks |
| Calc | S=I/J | d=root | parallel |
| Check | resistance | temp | verify |
Current density J equals I over S with 4 to 8 A per mm2 depending on cooling and slot fill kept 70 to 80 percent. Compute wire from phase current and J then verify it fits the slot; never exceed J 8 or fill 85 percent or the winding overheats or will not wind.
The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Rotating machine design see IEC 60034-1 and electrical safety see GB/T 5226.1. Always check the device datasheet and the product design file for ratings and derating.
Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.