A power factor meter wired wrong reads off by a wide margin, and three phase work adds polarity traps of its own. This page walks through single phase wattmeter connections, the two wattmeter method, and the mistakes that field crews actually make.
For single phase circuits, connect an electrodynamometer wattmeter with the current coil in series with the line and the voltage coil across the load, marking the polarity terminal toward the source; reversed polarity drives the pointer backward. Compute the power factor as P divided by the product of U and I. A modern clip-on power meter is faster: clamp the line and read the factor directly, provided the instrument range covers the load current, commonly 0.5 to 600 A.
On a three phase three wire system use the two wattmeter method: voltage coils across Uab and Ucb, current coils in phases A and C, total power P1 plus P2, and the factor equals total power divided by the square root of three times U times I. For a four wire system, measure each phase separately with three elements or a weighted three phase clamp and sum the results. Phase angle meters read cos phi directly from the angle between U and I, but the clamp direction must match the arrow. Typical traps: swapping a voltage lead such as Uac flips the sign and can yield a negative factor, clamping both line and neutral at once cancels the field and reads zero, and variable frequency drives demand a true RMS instrument that tolerates harmonic content, because ordinary meters misread PWM output by 5 to 10 percent.
| Item | Single phase | Three phase 3-wire | Three phase 4-wire |
|---|---|---|---|
| Instrument | Wattmeter or clamp | Two wattmeters | Three elements or weighted clamp |
| Current connection | Series in the line | Series in A and C | Each phase separately |
| Voltage connection | Across the load | Uab and Ucb | Each phase to neutral |
| Reading | P/(U I) | (P1+P2)/(1.732 U I) | Sum P/(1.732 U I) |
| Caution | Polarity to the source | Guard against swapped leads | Do not clamp the neutral |
Prefer a true RMS clamp-on power meter in the field and back-calculate from P divided by U I when the angle is unavailable. VFD loads require instruments rated for distorted waveforms.
The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: General requirements for electrical measuring instruments are given in GB/T 22264, energy metering in the GB/T 17215 series, with installation practice per IEC 62053 and IEC 60204-1. Always check the device datasheet and the product design file for ratings and derating.
Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.