MOULDLKnowledge BaseElectrical Knowledge Base3D Model DownloadsMembership
中文版Model Store »
Knowledge Base › Electrical Knowledge Base › Source transformation: real voltage and current source models
HomeModels
Table of contents

On this page

Electrical & Electronic Basics (600 articles)

Quick Reference

  • PLC & Programming
  • Electrical & Electronic Basics (monthly)(每月更新中)
  • Electrical Control & Drawings (monthly)(每月更新中)
  • Drives & Actuators (monthly)(每月更新中)
  • Sensors & Detection (monthly)(每月更新中)
  • Industrial Communication & Networks (monthly)(每月更新中)
  • HMI & Host Systems (monthly)(每月更新中)
  • Industrial Robots & Motion Control (monthly)(每月更新中)
  • Mechatronic System Integration (monthly)(每月更新中)
  • Fault Diagnosis & Standards (monthly)(每月更新中)

Source transformation: real voltage and current source models

Practical sources are EMF+series r or Is+parallel r; both describe the same load line.

1. How it works

Equivalence: E=Is×r with matching polarity; valid for the external circuit, not for internal losses.

2. Practice and pitfalls

Use transformations to simplify mixed-source networks; maximum-power matching (efficiency 50%) suits signals, not power systems.

3. Source model quick table

SourceModelTransformTypical object
BatteryE + series rIs=E/r12V car battery
PhotodiodeIs + parallel rE=Is×rLight sensing
Sensor outputHigh-Z voltageTreat as current sourcePiezo, photovoltaic
Regulated supplyNear-zero rLoad regulationSMPS
Current mirrorHigh-Z current sourceFlat load lineBias networks
TransformerImpedance as rShort-circuit testDistribution trafo

4. Notes

Apply the points above to Source transformation; the figures are typical engineering values, so confirm them against the device datasheet and the actual design before release.

5. References

The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Per GB/T 4728, GB/T 19826 and the corresponding IEC documents. Ratings and derating follow the device datasheet and the product design file. Always check the device datasheet and the product design file for ratings and derating.

6. Cautions

⚠️ Three common pitfalls:
① Treating transformed models as physical reality
② Transforming controlled sources carelessly
③ Applying power-match to power systems

Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.

Related reading

Related 3D models: Ready to build it? Download free 3D models & CAD drawings at MOULDL »
MOULDL · Electrical Knowledge Base · free self-study reference for electrical & automation engineers, 3D CAD models at MOULDL