Laptop bricks and PC supplies advertise active PFC, but what does the circuit actually do inside? This page contrasts passive and active power factor correction and lists the service traps around the 400 V bus.
Passive PFC widens the current conduction angle with a large input inductor or a tuned valley fill network, lifting the factor from about 0.6 to roughly 0.8. It is cheap and rugged but bulky and only effective below roughly 100 W, so small adapters favor it. The DC bus structure stays conventional, and in service you merely confirm the inductor is not shorted or open.
Active PFC inserts a boost converter between the bridge and the bus: a MOSFET switches at tens of kilohertz and forces the input current to follow the voltage sine, achieving 0.95 to 0.99 with current THD under 10 percent, while holding the bus near 380 to 400 V. Identify it by the nameplate claim of active PFC or PF above 0.95. Supplies with passive PFC start hard on generators and UPS units; active PFC inputs look almost resistive and behave better upstream. In repair, remember the PFC stage is live at 400 V: wait a minute or two and discharge the bus capacitor through a resistor before touching, verify the PFC inductor for opens and the MOSFET for shorts, since a dead PFC stage leaves the bus low and the supply unable to carry load.
| Item | Passive PFC | Active PFC |
|---|---|---|
| Power factor | 0.7 to 0.8 | 0.95 to 0.99 |
| Current THD | High | Under 10% |
| Cost | Low | Medium to high |
| Volume | Large | Small |
| Power range | Under 100W | Above 75W |
| Service focus | Inductor | MOSFET and control IC |
Equipment above 75 W is expected to carry PFC under efficiency rules. During repair the 400 V active PFC bus must be discharged and verified before any contact.
The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Harmonic current limits are set by GB 17625.1, with switch mode supply safety per IEC 62368 and IEC 60204-1. Always check the device datasheet and the product design file for ratings and derating.
Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.