When a rectifier filter fails the waveform tells the story: missing half cycles, big spikes or distorted ripple each point to a specific fault. This page teaches how to read the scope and locate the fault.
After a bridge rectifier and filter the trace should be DC with small regular sawtooth ripple whose frequency is 100 Hz for 50 Hz full wave. On AC coupling the ripple is a tidy saw or triangle, and on DC coupling the bus is steady with no big sag. Remember that picture; anything else stands out. Use the shortest ground and 20 MHz limit or ringing fools you.
Only 50 Hz ripple means one diode is open and it became half wave. Huge ripple with regular notches means the filter cap lost capacitance or opened and the bus sags with each peak. High frequency ringing on top points to high ESR or long leads, and periodic clipping means the load overloads or regulation acts. Low bus with big ripple means a bridge arm is broken.
| Wave sign | Likely fault | Action |
|---|---|---|
| 50 Hz ripple | half wave | check one diode |
| Huge notch | cap lost | swap cap |
| HF ring | high ESR | low ESR short |
| Period clip | load over | check load |
| Low sag | bridge arm | swap bridge |
| Cap ok load bad | wiring | tighten |
First use AC coupling to read ripple frequency and tell half from full wave, then DC to see bus sag, comparing cap end with load end to locate the fault. Short ground, 20 MHz limit, load it, and do not trust ringing.
The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Power test and diagnosis per GB/T 5226.1; scope use to GB/T 19862 and IEC 60204-1. Always check the device datasheet and the product design file for ratings and derating.
Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.