The permitted number of starts in a nameplate is not arbitrary; repeated starting overheats the rotor to the point of distortion. This page states the cold and hot limits and how to choose a motor for frequent duty.
Direct-on-line starting draws 5 to 7 times rated current for a fraction of a second to a few seconds, and most heat lands in the rotor. Standards allow two consecutive starts from cold (stationary at least 4 hours) with a 5 minute gap, and only one start from hot (just stopped). With heavy load or high inertia the count must be reduced further.
Repeated starting stacks rotor temperature because the bars and end rings cannot shed heat in time. Exceeding the B-class 130 C or F-class 155 C limit ages insulation fast or punctures it on the spot, and cage bars can loosen from thermal stress. For duties of tens of starts per hour use an S4 motor or a larger frame with a VFD, and de-rate the equivalent continuous load by 20 to 30 percent.
| State | Consecutive starts allowed | Minimum interval | Remark |
|---|---|---|---|
| Cold, off 4 h or more | 2 starts | 5 min | Let it cool between |
| Hot, just stopped | 1 start | Full cooling | No repeat starts |
| Duty S4 | Per design cycle | Per load | Dedicated motor |
| Heavy load, high inertia | Fewer starts | Extended | Check datasheet |
| VFD or soft start | Frequent OK | Short OK | Low current |
Convert the real start/stop frequency into an equivalent continuous duty when selecting a motor; for frequent starting choose an S4-duty motor or add a VFD outright. Repeated cold starts beyond the limit are the most common man-made cause of burnt rotors on site. Stick to the cold-2, hot-1 rule.
The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Duty cycles and ratings of rotating machines: GB/T 755 (IEC 60034-1); electrical safety: GB/T 5226.1. Always check the device datasheet and the product design file for ratings and derating.
Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.