Inovance servo is widely used in non standard equipment in China and its menu differs from import brands. This page uses SV660 as example to walk through initialization motor identify and basic running parameters.
After power on first enter H0 group motor parameters and confirm motor code H0-00 matches the connected motor or torque will be abnormal. Then run static identify and inertia identify so the drive learns the motor and load. Wrong motor code causes low speed shake and weak torque.
Step two set control mode H0-01: 0 position 1 speed 2 torque. Set electronic gear ratio H0-05 H0-06 per calculation. Step three set direction and I O and travel limits. Finally run auto gain to set rigidity and set in position window and over error. On site rule: identify before tune jog before auto. Pit one wrong motor code low speed shake; pit two inertia identify with axis jammed gives garbage.
| Step | Parameter | Setting | Effect |
|---|---|---|---|
| Motor match | H0-00 | correct code | normal torque |
| Identify | H0-3x | static inertia | learn motor |
| Mode | H0-01 | 0/1/2 | position speed torque |
| Gear | H0-05/06 | calc | pulse per mm |
| Gain | auto | rigidity | stable |
| Window | H0-xx | set | in position |
Setup order: confirm motor code then static and inertia identify then mode gear direction IO then auto gain rigidity then in position and over error windows. Always jog after identify and never identify with a jammed axis.
The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Servo parameter and safety see GB/T 5226.1 and drive interface see IEC 61800-3. Always check the device datasheet and the product design file for ratings and derating.
Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.