Electricians compute how much force a motor has using the conversion among torque speed and power. This page gives the core formula unit conversion and three quick examples.
The relation is power P in kW equals torque T in N m times speed n in rpm divided by 9550; conversely torque T equals 9550 times P divided by n. So torque is inversely proportional to speed at fixed power and proportional to power at fixed speed. This is the daily workhorse formula.
Units: power commonly kW but also HP where 1 HP is about 0.746 kW; torque has N m and sometimes kgf m where 1 kgf m is about 9.8 N m. Examples: a 4 kW motor at 1450 rpm gives T equal 9550 times 4 over 1450 about 26.3 N m; a 7.5 kW at 3000 rpm gives about 23.9 N m showing lower speed gives more torque. Pit: mixing kW with W or HP with kW gives thousand times error; using sync speed instead of rated speed gives wrong torque.
| Case | Known | Formula | Result |
|---|---|---|---|
| Ex1 | 4kW 1450 | T=9550P/n | 26.3 N m |
| Ex2 | 7.5kW 3000 | T=9550P/n | 23.9 N m |
| Ex3 | 10HP 1500 | HP to kW first | convert |
| Unit | kW rpm Nm | T=P9550/n | base |
| Pit | kW as W | 1000x error | wrong |
| Pit2 | sync speed | not rated | wrong T |
Core formula T equals 9550 times P over n with P in kW n in rpm T in N m; torque is inverse to speed at fixed power. Watch units: 1 HP is 0.746 kW and use rated not synchronous speed or torque is wrong by the slip percent.
The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Rotating machine characteristics see IEC 60034-1 and electrical safety see GB/T 5226.1. Always check the device datasheet and the product design file for ratings and derating.
Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.