MOULDLKnowledge BaseElectrical Knowledge Base3D Model DownloadsMembership
中文版Model Store »
Knowledge Base › Electrical Knowledge Base › Op amp gain-bandwidth product and frequency response limits
HomeModels
Table of contents

On this page

Electrical & Electronic Basics (600 articles)

Quick Reference

  • PLC & Programming
  • Electrical & Electronic Basics (monthly)(每月更新中)
  • Electrical Control & Drawings (monthly)(每月更新中)
  • Drives & Actuators (monthly)(每月更新中)
  • Sensors & Detection (monthly)(每月更新中)
  • Industrial Communication & Networks (monthly)(每月更新中)
  • HMI & Host Systems (monthly)(每月更新中)
  • Industrial Robots & Motion Control (monthly)(每月更新中)
  • Mechatronic System Integration (monthly)(每月更新中)
  • Fault Diagnosis & Standards (monthly)(每月更新中)

Op amp gain-bandwidth product and frequency response limits

A stage that amplifies ten times nicely collapses at high frequency when you ask for one hundred, the gain-bandwidth product is the wall. This page shows how GBW sets the usable bandwidth and how to trade gain against bandwidth.

1. How it works

Open-loop gain falls at 20dB per decade, so gain times bandwidth stays roughly constant, the GBW. With TL071 at 3MHz, a closed-loop gain of 10 keeps about 300kHz of bandwidth, gain 100 leaves 30kHz and gain 1000 leaves 3kHz. To want both high gain and wide bandwidth you either pick a higher-GBW part or split stages, per the open-loop curves in the datasheet and GB/T 4728.

2. Numbers and practice

Estimate bandwidth as GBW over the closed-loop gain, then keep a 5 to 10 times margin: amplifying a 20kHz signal at 50 times needs 1MHz nominally, so choose a 10MHz part such as TLE2072, or phase lag and amplitude droop will round your square edges. Cascaded stages narrow the total, two 30kHz stages give about 19kHz combined, so budget gain across stages with the total in mind.

3. Pitfalls and fixes

Check the datasheet GBW first, then slew rate for square and large signals, and the weaker one rules. Traps: treating GBW as the working frequency with no margin, so a 1MHz part at gain 10 barely covers 100kHz with poor flatness; skipping decoupling on one stage of a cascade and losing bandwidth there; and forgetting that a capacitor across the feedback resistor adds a pole that eats bandwidth by itself. On the bench, a square wave with rounded edges or overshoot is your bandwidth or stability alarm.

4. Gain-bandwidth quick reference

PartGBWBandwidth at gain 10
LM3581MHzabout 100kHz
TL0723MHzabout 300kHz
TLE207210MHzabout 1MHz
OP070.6MHzabout 60kHz
OPA627 wideband16MHzabout 1.6MHz
Design margin5 to 10 timesmultiply the need

5. Notes

GBW math fits every AC stage, filter and active probe. Pick parts by target frequency times gain times a 5 to 10 margin, budget the total bandwidth across cascades, and verify slew rate for large signals, both boxes ticked or the stage is not really usable.

6. References

The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Op amp frequency response per GB/T 4728; safety IEC 60204-1. Always check the device datasheet and the product design file for ratings and derating.

7. Cautions

⚠️ Three common pitfalls:
① Selecting a part with zero margin against GBW: a 1MHz op amp at gain 10 barely flattens 100kHz
② Ignoring total bandwidth across cascaded stages: each stage is fine alone, the chain droops
③ Reading GBW but not slew rate: large square waves come out as triangles

Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.

Related reading

Related 3D models: Ready to build it? Download free 3D models & CAD drawings at MOULDL »
MOULDL · Electrical Knowledge Base · free self-study reference for electrical & automation engineers, 3D CAD models at MOULDL