Servo encoder types and resolution explained

The small box at the motor end is the encoder and it decides how fine a position the system can resolve. This page explains incremental absolute and resolver encoders and how to read their resolution so you stop mixing them up.

1. How it works

The encoder sits on the shaft and outputs a signal proportional to angle. An incremental encoder outputs two quadrature square waves A and B plus a Z zero pulse. An absolute encoder outputs a unique code for every angle so position is known at power on. A resolver is rugged and immune to noise used in harsh sites.

2. Practice and pitfalls

Resolution for incremental equals line count times four because of quadrature: 1000 lines gives 4000 pulses per turn and with a 1:5 gearbox the per turn count multiplies five times. Absolute resolution is given in bits such as 17 bit equals 131072 counts per turn. Choose by need: ordinary conveyors use 1000 to 2500 lines while multi axis sync and CNC use 17 bit or above.

3. Encoder type and resolution reference

TypeResolutionPower loss memoryUse
Incremental 10004000 pprno need homegeneral
Incremental 250010000 pprno need homefaster
Absolute 17 bit131072 ppryes no homeCNC multi axis
Resolverrough robustyesharsh site
Multiturn absbits x turnsyes batterylong travel

4. Notes

Select by accuracy need: general conveyors use 1000 to 2500 line incremental while multi axis sync and CNC use 17 bit absolute. Keep the shield grounded at one end and never hammer the code disk during coupling fit.

5. References

The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Encoder and interface standard refer to IEC 61800-3 and electrical safety refer to GB/T 5226.1. Always check the device datasheet and the product design file for ratings and derating.

6. Cautions

⚠️ Three common pitfalls:
① Forgetting the times four factor makes real resolution four times lower
② Absolute encoder battery dead but still trusted loses origin
③ Hammering the coupling breaks the fragile code disk at once

Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.