Voltage divider and current shunt: formulas and typical applications

Divider: Uout=U×R2/(R1+R2); shunt splits current inversely with resistance.

1. How it works

Keep the divider impedance low enough for ADC input but light on the source; 62k+10k maps 24V to 3.3V.

2. Practice and pitfalls

Shunt resistors need power and temperature-coefficient checks (manganin for high current); beware loading on both networks.

3. Typical divider/shunt values

ApplicationNetworkValuesKey point
24V→3.3V ADCDivider62k+10kZin ≥1MΩ
Bus voltage senseDivider+bufferOp-amp followerLoading
Current sensingShunt0.01~0.1Ω manganinPower budget
Ammeter extensionParallel shuntPer meter resistanceWire gauge
Signal attenuationMatched dividerImpedance matchStray capacitance
Bias settingDivider+followerOp-amp isolatedDrive ability

4. Notes

Ratio accuracy comes from paired resistors, not absolute tolerance; matched pairs beat expensive singles.

5. References

The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Resistor series per GB/T 2471, IEC 60115; design per op-amp and ADC datasheets. Always check the device datasheet and the product design file for ratings and derating.

6. Cautions

⚠️ Three common pitfalls:
① Driving a divider straight into a low-Z load
② Ignoring shunt self-heating
③ Buying precision singles instead of matched pairs

Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.