Two SPDT switches cross-connect their travellers; either switch toggles the lamp - XOR logic.
Three locations add one intermediate (DPDT cross) switch; n locations need n−2 of them.
Verify with a continuity tester to find the common terminal, then cycle every switch twice; wrong traveller wiring shows as 'one switch dead'.
| Locations | Switches | Travellers | Note |
|---|---|---|---|
| Two | 2× SPDT | 2 | Standard |
| Three | 2+1 intermediate | 4 | Cross DPDT |
| Four | 2+2 | 6 | Chained |
| n | 2+(n−2) | 2(n−1) | Grows linearly |
| Wireless relay | — | — | No new wires |
| Smart switch | — | — | Neutral version for LED |
Apply the points above to Two; the figures are typical engineering values, so confirm them against the device datasheet and the actual design before release.
The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Per GB 16915.1, GB 50034 and the corresponding IEC documents. Ratings and derating follow the device datasheet and the product design file. Always check the device datasheet and the product design file for ratings and derating.
Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.