A voltage multiplier stacks capacitor charge pumps to turn low AC into several times the DC, used for high voltage at low current. This page covers doubler to N multiplier topologies and selection notes.
A classic half wave doubler uses two caps and two diodes. On one half cycle D1 charges C1 to the peak; on the other D2 adds that onto C2, giving about twice the peak at C2. It is not a transformer boost but a capacitor charge pump in series, so with tiny load the voltage nears two times root two of the AC and sags as load grows.
Cascading doublers gives triple, quadruple or N times voltage, each stage stacking another peak. More stages raise no load voltage but make load ability and per stage voltage rating harsher, and ripple worsens with stages. The last cap takes the full voltage, so rate every cap by the maximum possible and keep equal values or sharing goes wrong.
| Stages | No-load V | Note |
|---|---|---|
| Doubler | about 2 peak | common |
| Tripler | about 3 peak | mid HV |
| Quad | about 4 peak | ripple up |
| N mult | N peak | share evenly |
| Loaded | sags | low current |
| Shorted | cap dumps | blows parts |
Multipliers suit high voltage low current jobs where size matters, like HV tanks, static and flash. Rate every stage for voltage and add a bleed resistor; the load must never short because the cap dump destroys parts, and the stored HV can kill.
The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: High voltage rectifier and low current supply per GB/T 5226.1; clearance to IEC 60204-1 and GB/T 16935. Always check the device datasheet and the product design file for ratings and derating.
Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.