Thermal design and heatsink for linear regulators

With a linear regulator the whole drop becomes heat, so thermal design done wrong blows the part. This page covers junction temperature, thermal resistance and how to size the sink.

1. How it works

Junction temperature Tj equals Ta plus P times R theta ja, where R theta ja is the total junction to ambient resistance, the sum of junction to case, case to sink and sink to ambient. Loss P is (Uin minus Uout) times I. At 7 V drop and 1 A, P is 7 W; with total resistance 10 C per W rise is 70 C, so at 40 C ambient junction is 110 C, fine, but at 20 C per W it hits 180 C and fails. The sink decides life or death.

2. Practice and pitfalls

Invert the allowed rise to get needed total resistance: R theta ja at most (Tj max minus Ta) over P. Pick a sink by its R theta sa and lower R theta cs with grease. Natural convection small sinks are a few to tens of C per W; forced air is lower. Cap junction at 125 to 150 C, compute with margin using the hottest cabinet case like 60 C not room temperature, and sum losses for shared sinks.

3. Thermal and sink

ParamComputeValue
Loss P(Uin-Uout) I7V 1A = 7W
Tj maxunder 125 to 150margin
Tot Runder (Tj-Ta)/Pinvert
R sapick sinkadd grease
Ambientcabinetnot room
Dropnot too bigswitch

4. Notes

Linear thermal design uses Tj equals Ta plus P times R theta ja to find total resistance, then sizes a sink with grease and torque, computed at the hottest cabinet condition. A big drop at high current is unrealistic; switch instead, and do not forget the insulator for shock safety.

5. References

The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Thermal design per GB/T 5226.1; device thermal to IEC 60747 and GB/T 12350. Always check the device datasheet and the product design file for ratings and derating.

6. Cautions

⚠️ Three common pitfalls:
① No grease or loose screw doubles contact resistance and explodes junction.
② Computing at room temperature passes then fails hot in cabinet; use worst case.
③ Holding a big drop linearly needs a huge sink; switch the topology.

Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.