A MOS is rated for tens of amperes yet runs hot and current-limited in use, because of on-resistance. This page shows how to compute loss from Rds(on), how it rises with temperature, and how much margin to leave.
On-resistance is the equivalent drain-source resistance when fully on, given in the datasheet at a specified V_GS and temperature, for example IRF3205 lists Rds(on) at most 8 milliohm at V_GS 10V and 25C. It sets conduction loss P equals I squared times Rds(on). At 10A the loss is only 0.8W, but a 100 milliohm part loses 10W, over ten times worse, per GB/T 4728.
Compute loss and rise. At 10A through 8 milliohm the loss is 0.8W and a small sink controls it; through 50 milliohm it is 5W and needs a big sink. Worse, Rds(on) climbs about 1.5 to 2 times with junction temperature, so hot loss is far above the cold calculation. Select using the hot Rds(on), not the 25C rating.
Size margin from maximum current squared times hot Rds(on) to get P, then temperature rise from P times theta JA, and keep junction below 125C with ambient. Traps: calculate from the 25C rating and the hot doubling overheats; insufficient V_GS drives Rds up into the linear region and loss explodes; unequal parallel sharing overloads one device.
| Parameter | Meaning | Effect |
|---|---|---|
| Rds(on) | on resistance | sets loss |
| 25C rating | e.g. 8 mohm | cold ref |
| Hot | doubles | use for loss |
| Loss | I2R | 10A x 8m 0.8W |
| Rise | P x theta | under 125C |
| V_GS | low spikes | linear big loss |
Rds(on) work fits supply, motor drive and high-current switch selection. Use the 150C hot Rds(on) for loss and match the heatsink, and ensure V_GS meets spec, 10 to 12V for standard parts. Do not estimate optimistically from the 25C rating.
The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Power MOS parameters and thermal per GB/T 4728; safety IEC 60204-1. Always check the device datasheet and the product design file for ratings and derating.