A separately excited DC motor offers three places to change speed: armature voltage, field flux and armature resistance. Their ranges, smoothness and losses differ so much that the choice defines the whole drive system.
The characteristic equation names the three levers. Armature voltage shifts the no-load speed while the slope stays put, giving parallel characteristic lines: with a thyristor converter or PWM chopper this reaches a 1:10 to 1:20 range, stepless, over 90 percent efficient and constant-torque. Field weakening raises speed above base by shrinking flux, typically 1:1.5 to 1:3, constant-power in nature but softening the curve and limited by commutation and mechanical strength to about 1.5 to 2 times base speed. Series resistance keeps the no-load speed fixed and steepens the slope: stepwise, around 1:2, with efficiency under 50 percent at low speed.
Practical systems combine voltage control below base speed with field weakening above it, giving a 1:15 total range for machine tool spindles and rolling mills. Selection follows load type: constant-torque loads favor voltage control, constant-power take-up machinery favors field weakening, and both together justify the combined scheme. A field-failure relay is mandatory on any weakening scheme: if excitation collapses the flux vanishes and the machine runs away, so the drive must trip or limit speed.
| Method | Range and direction | Output nature | Main drawback |
|---|---|---|---|
| armature voltage | below base, 1:10~1:20 | constant torque | needs controlled supply, costly |
| field weakening | above base, 1:1.5~1:3 | constant power | soft curve, overspeed risk |
| series resistance | below base, about 1:2, stepped | constant torque (lossy) | resistor heat, low efficiency |
| voltage plus weakening | over 1:15 total | torque low, power high | complex control and protection |
| PWM chopper | below base, stepless | constant torque | high device ratings needed |
| dual-loop drive | over 1:10, droop under 1% | four-quadrant reversible | professional tuning required |
Calculate the load profile before retrofitting: constant-torque favors voltage control and constant-power favors weakening. Anything below 5 percent required droop rules out resistance control outright.
The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: See GB/T 3886.1 for semiconductor converter ratings in DC adjustable-speed drives; safety per GB/T 5226.1 (IEC 60204-1). Always check the device datasheet and the product design file for ratings and derating.
Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.