Bridge sensor signals are small and ride large common mode, and one mismatched resistor in a discrete difference amplifier wrecks the rejection. The instrumentation amp puts the whole problem inside the chip. This page compares the two.
The single-op-amp difference amplifier lives or dies by four matched resistors: with the ratios equal the output tracks the differential and rejects common mode. Ordinary 1 percent parts drag the CMR below 80dB, even 0.1 percent struggles past 100dB, and the two input impedances differ, one R1 and one R3 plus R4, so high-impedance sources convert common mode to differential. Changing gain means touching four resistors that interact, per GB/T 4728.
The instrumentation amplifier is three op amps: two non-inverting input stages with gigaohm input impedance, one external gain resistor RG setting the gain independently, on INA128 as one plus 50k over RG, and a factory-trimmed difference stage whose CMR is guaranteed at 100 to 120dB and improves with gain. Offset, drift and gain error run an order of magnitude better than home-built. The price is 5 to 20 times the cost and usually a dual supply, though single-supply parts like INA333 exist.
Choose by source and common mode: shunt sensing with low symmetric sources is fine discrete; bridges, long thermocouple lines and biopotentials go instrumentation. Traps: the REF pin driven by a plain divider lowers the CMR by its impedance, so buffer it; squeezing all the gain into one stage makes RG large and gain error worse, follow with an ordinary stage; single-supply in-amps still clip below the negative rail; and both approaches deserve an RC anti-alias filter at the inputs.
| Aspect | Discrete difference | Instrumentation amp |
|---|---|---|
| CMR | resistor matched, 80dB | guaranteed 100dB+ |
| Input impedance | unequal legs | gigaohm, symmetric |
| Gain setting | resistor ratios | one RG resistor |
| Offset and drift | depends on op amp | order better |
| Cost | cents | 5 to 20 times |
| Fit | low-Z, small CM | bridge, line, high-Z |
The choice fits load cells, strain gauges, thermocouples and shunt sensing. Budget the common mode and source impedance first; save with a discrete stage at 0.1 percent for low-Z duties, go instrumentation for the rest, buffer the REF pin, filter the inputs and follow with one ordinary gain stage.
The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Instrumentation amplifier practice per GB/T 4728; safety IEC 60204-1. Always check the device datasheet and the product design file for ratings and derating.
Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.