Eliminate to get P=I²R, P=U²/R and R=U²/P; pick by the common quantity (I in series, U in parallel).
Voltage squares: −10% supply means −19% power on heaters; +10% means +21% - thermal tuning must follow.
Motors need the power triangle (cosφ, η); P=U²/R is only for constant-resistance loads.
| Target | Formula | Example | Result |
|---|---|---|---|
| Current | I=P/U | 1500W/220V | 6.8A |
| Hot R | R=U²/P | 220²/1500 | 32.3Ω |
| Line loss | P=I²R | 6.8²×0.5 | 23W |
| Power at 198V | P=U²/R | 198²/32.3 | 1.21kW |
| Series resistor | (U−UF)/I | LED loop | See limiters |
| 3-phase power | √3·U·I·cosφ | 380×10×0.85 | 5.6kW |
Apply the points above to Combining Ohm's law with power formulas; the figures are typical engineering values, so confirm them against the device datasheet and the actual design before release.
The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Per GB/T 3102.5, GB/T 25447, GB 5959 and the corresponding IEC documents. Ratings and derating follow the device datasheet and the product design file. Always check the device datasheet and the product design file for ratings and derating.
Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.