Decoding duty types S1 to S9 on the nameplate

The S1 or S3 code decides whether the motor runs continuous or intermittent; wrong duty burns it fast. This page explains S1 through S9.

1. How it works

S1 is continuous duty at rated load non-stop, for ordinary pumps and fans. S2 is short-time duty within a limited period (10/30/60 min) then cooled long enough, for brief hoists. Simplest two. Using an S2 motor as S1 overheats because cooling was designed for intermittent use.

2. Numbers and practice

Periodic types S3~S8: S3 intermittent periodic without starting (duty factor 25/40/60%), S4 with starting, S5 with starting and electric braking, S6 continuous with varying load, S7 with start/brake continuous, S8 variable speed/load continuous. Higher number means more complex. Key is duty factor ED%, e.g. S3-40% means run 4 of 10 min.

3. Pitfalls and fixes

S9 is non-periodic variable load where load and speed swing widely near rated, for modern VFD complex duty. Practice: cranes use S3/S4 sized by ED% (lower ED allows a larger rated power); conveyors use S1; frequent reversing with brake uses S5/S7. Traps: S1 motor on S3 crane overheats under frequent start; an ED40% motor used at ED60% is overloaded; ignoring the S code assuming equal power is universal. The S code and ED% must match real duty.

4. Duty type meanings

CodeMeaningEquipment
S1ContinuousPumps fans
S2Short timeBrief hoist
S3IntermittentCrane
S4With startFrequent
S9AperiodicVFD complex

5. Notes

S1 continuous, S2 short, S3~S8 intermittent or variable, S9 aperiodic variable. Cranes size by ED%; lower ED allows bigger rated power. Conveyors S1, reversing with brake S5/S7. Duty must match real service, not equal power.

6. References

The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Machines per IEC 60034-1; duty per GB/T 755. Always check the device datasheet and the product design file for ratings and derating.

7. Cautions

⚠️ Three common pitfalls:
① S1 motor on S3 crane overheats
② ED40% motor at ED60% is overloaded
③ Ignoring S code; equal power not universal

Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.