UC=U(1−e−t/τ) with τ=RC; landmarks 63.2% @1τ, 95% @3τ, 99.3% @5τ.
Current starts at U/R (inrush!) and decays exponentially; charging dissipates CU²/2 in R - 50% efficiency by nature.
Scope method: cursor to 63.2% of final value gives τ directly.
| Time | VC | I (relative) | State |
|---|---|---|---|
| 0 | 0 | 100% | Inrush |
| 1τ | 63.2% | 36.8% | Usual threshold |
| 2τ | 86.5% | 13.5% | Settling |
| 3τ | 95.0% | 5.0% | Nearly done |
| 5τ | 99.3% | 0.7% | Full (engineering) |
| 10τ | ≈100% | ≈0 | Complete |
Apply the points above to RC charging; the figures are typical engineering values, so confirm them against the device datasheet and the actual design before release.
The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Per GB/T 3102.5, GB/T 15289 and the corresponding IEC documents. Ratings and derating follow the device datasheet and the product design file. Always check the device datasheet and the product design file for ratings and derating.
Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.