A dead start capacitor gives the motor a very characteristic behaviour: a hum but no spin. This page lists the signs of open, degraded and shorted capacitors and how to confirm quickly with a capacitance meter.
An open or severely degraded start capacitor, below about 60 percent of value, weakens phase split so start torque vanishes; the motor hums and will not turn, yet a hand push gets it slowly running because a spinning rotor self-sustains on one winding. That hum-without-turn is the classic sign. Near the critical value it starts very slowly with high current and overheating.
An internal short turns the capacitor into a wire; the start winding is directly across the supply, current surges, the winding smokes and the breaker trips. Unlike the open case, a short draws big current the instant power is applied, so it is more dangerous. Measure the capacitor discharged; a reading near 0 ohm or far below rating means failed. Replace with the same self-healing 450 V AC part; if it has overheated long, re-measure winding insulation because the winding may also be damaged.
| Fault | Symptom | Measured | Action |
|---|---|---|---|
| Open | Hums, will not turn | OL | Replace |
| Degraded | Slow to start | <60% value | Replace |
| Shorted | Smoking, hot | approx. 0 ohm | Replace, check winding |
| Bulged | Case swollen | Low value | Replace |
| Leaking | Oil seepage | Failed | Replace |
A failed start capacitor announces itself as a humming motor that will not turn but spins when flicked by hand (open or degraded), or as instant smoke and heat (shorted). Measure on the capacitance range: below 60% of rated value, replace; a short reads near zero ohms. Fit the same rating in a 450 V AC self-healing film type, and if it cooked for long, re-test the winding insulation too.
The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Capacitors: GB/T 3667 / IEC 60252; single-phase motors: GB/T 12350. Always check the device datasheet and the product design file for ratings and derating.
Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.