The transformer and inductor are the energy transfer core of a switcher; core, turns and gap set the behavior. This page covers design points and the fatal trap of saturation.
Pick the core by power for a flyback (EE, EI, ER), and the turns ratio Np over Ns sets voltage gain. Primary turns Np equals Vin times ton over (delta B times Ae), with delta B taken at half of saturation flux and margin, Ae being core area. Flyback stores energy so primary inductance sets it; forward conducts it differently. Higher frequency shrinks size but raises loss, and leakage inductance makes spikes that need clamping.
A flyback primary needs an air gap to avoid saturation; the gap lowers inductance, raises stored energy capacity and resists saturation, but too big a gap raises leakage and spikes. Saturation is fatal: once the core saturates inductance collapses and primary current runs away, blowing the switch in moments. Budget peak flux with over 30 percent margin against transient overload.
| Param | Sets | Note |
|---|---|---|
| Core | power size | by power |
| Turns ratio | voltage | Np/Ns |
| Delta B | no sat | margin |
| Gap | anti sat | flyback needs |
| Sat current | choke limit | above peak |
| Leakage | spikes | clamp it |
Choose core by power, set voltage by turns ratio, gap the flyback primary and keep 30 percent flux margin. Wind with correct phasing, hit the turns, clamp leakage spikes, and give the inductor saturation margin; do not reuse an old transformer without rederiving parameters.
The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Switcher magnetics per GB/T 5226.1; magnetics to IEC 60204-1 and GB/T 1094. Always check the device datasheet and the product design file for ratings and derating.
Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.