MOULDLKnowledge BaseElectrical Knowledge Base3D Model DownloadsMembership
中文版Model Store »
Knowledge Base › Electrical Knowledge Base › The three elements of a sine wave and how to read the trace
HomeModels
Table of contents

On this page

Electrical & Electronic Basics (600 articles)

Quick Reference

  • PLC & Programming
  • Electrical & Electronic Basics (monthly)(每月更新中)
  • Electrical Control & Drawings (monthly)(每月更新中)
  • Drives & Actuators (monthly)(每月更新中)
  • Sensors & Detection (monthly)(每月更新中)
  • Industrial Communication & Networks (monthly)(每月更新中)
  • HMI & Host Systems (monthly)(每月更新中)
  • Industrial Robots & Motion Control (monthly)(每月更新中)
  • Mechatronic System Integration (monthly)(每月更新中)
  • Fault Diagnosis & Standards (monthly)(每月更新中)

The three elements of a sine wave and how to read the trace

A sine needs only three numbers to be drawn completely: amplitude, frequency and initial phase. This page shows how to read those three from an oscilloscope trace using the graticule and the time base.

1. How it works

The three elements are amplitude U peak, frequency f, and initial phase phi, so the wave is U peak sine of two pi f t plus phi. Amplitude sets the height, frequency sets how many divisions one cycle spans, and phase sets where it starts at time zero. Fix these three and the whole curve is known.

2. Practice and pitfalls

Read amplitude from peak-to-peak over two times the V per div. Read period from the divisions of one cycle times the time base, then f equals one over T. Read phase from the offset of the zero crossing against the t equals zero graticule, phi equals minus 360 times delta t over T. At 50 Hz the period is 20 millisecond.

3. Reading the trace

ElementHowFormula
AmplitudeVpp/2 x V/divUm = Up-p/2
RMSamp / 1.414U = Um/root2
Perioddiv x time/divT = N x t/div
Frequency1 / periodf = 1/T
Phasedelta tphi = -360 dt/T
Stableset triggerlevel mid

4. Notes

Reading traces is basic skill. Always confirm probe ratio, V per div, time base and trigger before measuring. In a hurry people skip these and the reading lands an order of magnitude off, blaming the machine instead of the scope.

5. References

The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Scope measurement follows GB/T 15289 and IEC 61010. Always check the device datasheet and the product design file for ratings and derating.

6. Cautions

⚠️ Three common pitfalls:
① Leaving the probe at 1X in software gives a tenfold amplitude error
② Untrimmed vernier makes each division wrong so frequency is off
③ Wrong trigger source makes the trace run and phase unreadable

Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.

Related reading

Related 3D models: Ready to build it? Download free 3D models & CAD drawings at MOULDL »
MOULDL · Electrical Knowledge Base · free self-study reference for electrical & automation engineers, 3D CAD models at MOULDL