Resistive sensor sampling and signal conditioning

Simple dividers suit rough indication; Wheatstone bridges handle strain gauges and RTDs; constant-current drive suits 3-wire RTDs.

1. How it works

Conditioning: instrumentation amplifier for mV bridge outputs, RC filtering, isolation when common-mode voltage is high.

2. Practice and pitfalls

Wiring: 2-wire RTD adds lead error, 3-wire cancels it, 4-wire removes it; shield grounded at one end only.

3. Sampling method comparison

MethodOutputSuitableWatch
Simple dividerNonlinearRough, potsLoading
Wheatstone bridgeNear-linear deltaStrain, RTDNull and drift
Constant currentU=I×R linear3-wire RTDSource accuracy
3-wire wiringCancels leadsIndustrial RTDEqual leads
4-wire wiringLead-freePrecision labCost
4-20mA loopCurrent linkLong distanceSense resistor

4. Notes

Apply the points above to Resistive sensor sampling and signal conditioning; the figures are typical engineering values, so confirm them against the device datasheet and the actual design before release.

5. References

The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Per GB/T 30121, IEC 60751, GB/T 17799 and the corresponding IEC documents. Ratings and derating follow the device datasheet and the product design file. Always check the device datasheet and the product design file for ratings and derating.

6. Cautions

⚠️ Three common pitfalls:
① Two-wire RTD on long cables
② Grounding shields at both ends
③ Overdriving the bridge for sensitivity - self-heating

Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.