Ripple factor of rectified output and how to measure it

Ripple factor measures how much AC rides on the DC output, and it is the hard indicator of how clean a supply is. This page defines the factor and shows two ways to measure it with a scope and a true RMS meter.

1. How it works

Ripple factor gamma equals RMS ripple over the DC component. For a 24 V average with 0.5 V RMS ripple gamma is about 2.1 percent. Linear supplies usually want under 1 percent, while switching supplies relax the rule but stay within rating. Note that RMS and peak to peak are different: a scope mostly reads Vpp and a meter reads RMS, and for sine Vpp is about 2.83 times RMS.

2. Practice and pitfalls

For scope measurement use AC coupling, 20 MHz bandwidth limit and the shortest ground lead, or you pick up switching noise and ringing. Read Vpp and convert by waveform; set attenuation and vertical gain to see the spikes, and use a ground spring instead of a long lead. Take the settled typical value, never a single spike.

3. Ripple factor versus measuring method

WaveformPk-pk to RMSBest meter
SineVpp about 2.83 Vrmsmeter or scope
Mains ripplenear trianglemeter good
Switch noisenot sinescope only
Spikeread Vppscope AC coup
No loadsmallerload it
Heavy loadlargeras used

4. Notes

Decide peak to peak or RMS first; use a true RMS meter for mains ripple, and a scope for switching supplies to see spikes. In every case load the supply and use a short ground lead so the reading reflects real conditions.

5. References

The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Power measurement per GB/T 5226.1 and IEC 60204-1; instrument use to GB/T 19862. Always check the device datasheet and the product design file for ratings and derating.

6. Cautions

⚠️ Three common pitfalls:
① Measuring ripple with a normal multimeter AC range misreads badly on HF; use a true RMS meter.
② Long scope ground lead picks up ringing; use a ground spring and shortest lead.
③ Forgetting to load the supply gives far smaller ripple and a false pass.

Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.