Motor selection torque and speed verification steps

Selecting a motor cannot only watch power; verification of torque and speed is the key to whether it works. This page gives a complete verification flow from load to motor so you will not fail.

1. How it works

Step one: compute load torque and speed demand. Turn the process into numbers: load steady torque T_L measured per el-994 or by formula working speed n from cycle or line speed and acceleration peak torque T_peak. Example: a conveyor needs 20 N m steady 1500 rpm start peak 35 N m. Also reflect load inertia to motor shaft per el-993 ready for check.

2. Numbers and practice

Step two: verify three motor indices. One speed: rated speed at or above working speed with frequency match if inverter. Two torque: rated torque at or above T_L times 1.2 margin and peak torque at or above T_peak within duty. Three inertia: reflected load inertia divided by rotor inertia at or below 10 or add a reducer. All three pass to be suitable; any marginal step up one size.

3. Pitfalls and fixes

Pit one: only watching power not torque buys a 2 pole motor for a 1000 rpm machine triple speed difference. Pit two: only 10 percent margin alarm on grid fluctuation. Pit three: inertia ratio 30 forced tuned jitters out of tolerance. Rule: torque before power steady by rated peak by acceleration inertia over 10 add reducer finally run loaded and recheck temperature and current.

4. Motor selection check table

StepCheckCriterionElse
1 demandT_L n T_peakfrom processrecompute
2 speedn_rated>=nfreq matchup size
3 torqueT_N>=1.2T_LT_peak okup size
4 inertiaJ<=10J_madd reducerreflect
5 runtemp currentrecheckadjust

5. Notes

First compute load steady torque working speed and acceleration peak then verify motor rated speed at or above working speed rated torque at or above load times 1.2 peak torque at or above acceleration peak and inertia ratio at or below 10; finally run loaded and recheck.

6. References

The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Motor selection see IEC 60034-1 and electrical safety see GB/T 5226.1. Always check the device datasheet and the product design file for ratings and derating.

7. Cautions

⚠️ Three common pitfalls:
① Only watching power not torque buys 2 pole for 1000 rpm triple speed
② Only 10 percent margin alarms on grid fluctuation
③ Inertia ratio 30 forced tuned jitters out of tolerance

Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.