Three ways to wire a potentiometer: divider, rheostat and buffered

Three-terminal divider sets a voltage; two-terminal rheostat (wiper tied to one end) trims current.

1. How it works

Always short the unused terminal on rheostat wiring or vibration noise appears; load must be ≥10× the pot value.

2. Practice and pitfalls

Power is U²/R over the full track regardless of wiper position; lock painted setpoints after tuning.

3. Potentiometer wiring comparison

WiringPinsUseKey point
Voltage dividerAll threeReference adjustLoad ≥10× R
RheostatTwo + jumperCurrent/gain trimShort unused pin
Buffered divider3 + followerPrecision setpointOp-amp isolation
Coarse+fineTwo potsFine tuning10:1 ratio
Multi-turn10-turn potPrecise set0.25% resolution

4. Notes

Apply the points above to Three ways to wire a potentiometer; the figures are typical engineering values, so confirm them against the device datasheet and the actual design before release.

5. References

The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Per GB/T 15298, GB/T 2470 and the corresponding IEC documents. Ratings and derating follow the device datasheet and the product design file. Always check the device datasheet and the product design file for ratings and derating.

6. Cautions

⚠️ Three common pitfalls:
① Leaving the third pin floating
② Loading the wiper directly
③ Rating power by wiper position

Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.