MOS parts split into N and P channel with opposite wiring: one sits at the low side, the other at the high side. This page compares their conduction conditions and how to pick a high-side or low-side switch.
Conduction polarity is opposite. An N-channel MOS conducts when V_GS exceeds V_th, the gate a few volts above the source. As a low-side switch the source is grounded and a positive gate turns it on, simple. A P-channel conducts when V_GS is below minus V_th, the gate a few volts below the source; as a high-side switch the source ties to supply positive and pulling the gate low turns it on. The source potential defines each, per GB/T 4728.
Pick by side. A grounded load uses an N-channel low-side switch driven straight by a high MCU level. A supply-side load uses a P-channel high-side switch turned on by pulling the gate to ground relative to the source. Using an N-channel high side needs the gate above the source, hence above the supply, requiring bootstrap or charge pump, which is complex. Convention: N low side, P high side.
Drive voltage matters. Logic-level parts have V_th about 1 to 2V and run from 5V; standard parts need 10 to 12V gate for full conduction and half-conduct, hence overheat, from 5V. Traps: wire a P-channel like N so a high gate turns it off; use N high side without raising the gate so it never conducts; drive a standard MOS from 3.3V and it half-conducts and burns. Confirm channel type and V_th when replacing.
| Aspect | N-channel | P-channel |
|---|---|---|
| Conduct | V_GS positive | V_GS negative |
| Use | low side | high side |
| Source | to ground | to supply |
| Gate | positive drive | pull low |
| Bootstrap | high side yes | usually no |
| V_th | 1 to 4 V | 1 to 4 V |
The comparison fits load switches, motor bridges and supply switching. Use N-channel low side driven directly, P-channel high side with gate pulled low, and give standard parts 12V gate drive. Do not flip the channel type or drive a standard part at low voltage.
The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: MOS devices and switching per GB/T 4728; safety IEC 60204-1. Always check the device datasheet and the product design file for ratings and derating.
Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.