Single-phase motors split into capacitor-start and capacitor-run families with very different start torque and efficiency. This page compares the structures, which gives more starting punch, and which load each suits.
Capacitor-start uses a large start capacitor plus a centrifugal switch; at standstill the capacitor gives high start torque of 2 to 3 times rated, and at 75 to 80 percent speed the switch cuts the start winding and capacitor out, leaving only the main winding. It starts hard but the start capacitor must not stay energised or it bursts, and the switch is an extra failure point. Good for compressors and pumps.
Capacitor-run keeps a smaller capacitor permanently in the auxiliary winding, with no switch. Start torque is only 0.3 to 1 times rated, but running efficiency, power factor and life are better and noise is lower, suiting fans and light continuous loads. Use a self-healing AC capacitor rated for continuous duty. For heavy start use capacitor-start-run with both capacitors. A failed run capacitor stops the motor; a failed start capacitor only kills starting.
| Item | Capacitor start CS | Capacitor run PSC | Comment |
|---|---|---|---|
| Starting torque | 2~3x | 0.3~1x | CS wins |
| Centrifugal switch | Yes | No | PSC simpler |
| Running efficiency | Average | High | PSC better |
| Capacitor | Large, temporary | Small, permanent | Different |
| Suitability | Hard starting | Light long runs | Per duty |
Choose capacitor-start for hard-starting loads where the big starting torque matters, and capacitor-run for light long-running duty where efficiency and life matter. The centrifugal switch of a CS motor is a wear part; the PSC capacitor must survive continuous duty. Identify the type before replacing a motor, because the failure signatures differ too.
The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Single-phase motors: GB/T 12350; motor capacitors: GB/T 3667 / IEC 60252. Always check the device datasheet and the product design file for ratings and derating.
Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.