Average and RMS are not the same, and a cheap meter reads an average then scales it, so it lies on non-sinusoidal waveforms. This page explains the difference and why a variable frequency drive needs a true RMS meter.
For a sine the full-wave average is 0.637 of peak while RMS is 0.707, a fixed 1.11 ratio that only holds for a clean sine. Average reflects the rectified mean, RMS reflects heating power. Once the wave is distorted that 1.11 link breaks and you cannot infer one from the other.
A cheap meter is average-responding: it rectifies the AC and scales by 1.11 to show RMS, so it is right only on a pure sine. On square, triangle or VFD PWM output the error reaches 10 to 40 percent. A true RMS meter squares, integrates and roots the instantaneous value, so it is correct for any shape and is worth keeping on the bench.
| Item | Avg-responding | True RMS |
|---|---|---|
| Principle | rectify scale | sq-integrate-root |
| Sine error | good | good |
| Square error | about +11 pct | good |
| On VFD | 30 pct low | good |
| Bandwidth | kHz | over 10 kHz |
| Price | low | high |
Keep a true RMS meter for drives, servo and switching supplies and use the cheap one only for sine mains. Read the True RMS mark before trusting a reading against drive parameters, or the whole line gets misjudged.
The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Meter standards follow GB/T 7676 and safety IEC 61010. Always check the device datasheet and the product design file for ratings and derating.
Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.