Wound rotor motors start by inserting resistance in the rotor circuit, but the resistor value must be calculated so starting torque is high and current low. This page gives the step starting resistance calculation and practical formulas so you can size each step.
Inserting starting resistance in the rotor circuit raises R2 over s in the equivalent circuit, shifting the torque speed curve downward so starting torque rises and starting current falls. Ideally each step begins near maximum torque by the torque ratio method, giving a smooth low current start. Resistance is switched in steps: maximum at standstill, shorted progressively as speed builds, finally all shorted for normal run. Values must be referred from the rotor rated data, not guessed.
From rotor rated EMF E2N, current I2N and resistance R2, set maximum start torque T1 at 1.5 to 2.5 times rated and transfer torque T2 at 1.1 to 1.2 times, with steps m of 2 to 4. The step ratio alpha is about square root of T1 over T2, and the external resistance of step k is R2 times (alpha to the k minus 1). For R2 0.1 ohm, T1 over T2 2 and m 3, alpha is about 1.26 and the external steps come to roughly 0.026, 0.058 and 0.098 ohm; verify start current stays under 2 to 3 times rated. In the field, switch steps when current falls to 1.2 to 1.5 times or speed reaches target, size the resistor bank by start frequency, use water resistance for frequent starts, and watch for broken resistor strips, oxidized terminals and carbon on the slip rings.
| Parameter | Symbol | Value or formula |
|---|---|---|
| rotor resistance | R2 | from E2N over I2N |
| max start torque | T1 over TN | 1.5 to 2.5 |
| transfer torque | T2 over TN | 1.1 to 1.2 |
| steps | m | 2 to 4 |
| step ratio | alpha | sqrt(T1 over T2) |
| step k external | R ext k | R2 times (alpha k minus 1) |
Refer resistance from rotor data, find step ratio alpha from T1 over T2 and compute each external step as R2 times (alpha to k minus 1), checking start current under 2 to 3 times rated. Switch on current falling to 1.2 to 1.5 times or speed reached, size the bank by start frequency and keep slip rings clean of carbon.
The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Rating per GB/T 755 (IEC 60034-1); test method per GB/T 1032. Always check the device datasheet and the product design file for ratings and derating.
Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.