A two dollar multimeter answers the diode question in ten seconds, but only if you read it correctly and know when the reading lies. This page covers the diode test mode, the resistance mode fallback, and the in circuit traps.
Set the meter to diode test and touch the red probe to the anode, black to the cathode: a good silicon diode shows 0.5 to 0.7 V, germanium 0.2 to 0.3 V, Schottky 0.2 to 0.4 V. Swap the probes and a good part reads overrange, OL. The meter actually sources a small constant current and reports the resulting drop, so the number is a junction measurement, not a resistance. Both directions showing near zero means the junction is shorted; both showing OL means it is open. Either way the part is dead.
The resistance mode still works on analog meters: forward shows a few hundred ohms to a few kilohms, reverse shows megohms, and the asymmetry is the diagnosis. Watch the meter polarity convention on analog instruments, where the black lead sits positive internally. The big trap is in circuit testing: parallel paths through other components fake a low reading in both directions and a perfectly good diode looks shorted. When in doubt, lift one leg or measure after desoldering, and remember that a diode can pass the diode test yet fail under load when it leaks hot or recovers slowly.
| Measurement | Normal display | Conclusion |
|---|---|---|
| Diode mode, forward | 0.2 to 0.7V | Red on anode, healthy |
| Diode mode, reverse | OL overrange | Blocking, healthy |
| Both directions conduct | Near 0V | Junction shorted, bad |
| Both directions OL | Overrange | Junction open, bad |
| Resistance mode | Small forward, large reverse | Asymmetry confirms health |
Diode mode red on anode reads 0.2 to 0.7 V and reverse reads OL on a healthy part; both conducting means shorted, both OL means open, and in circuit readings need one leg lifted to be trusted.
The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Semiconductor devices follow IEC 60747 and GB/T 4586, graphic symbols GB/T 4728, with meter practice per IEC 60204-1. Always check the device datasheet and the product design file for ratings and derating.