After rectifying AC to DC the link between RMS and average gets complicated. This page covers half-wave and full-wave rectification with and without capacitor filter, with a quick table for the bench.
Without filtering, half-wave rectified average is U peak over pi, about 0.318 U peak, with RMS half the peak; full-wave average is two U peak over pi, about 0.637, with RMS U peak over root two because power is unchanged. So full-wave average is twice half-wave, and the average is the useful DC while RMS drives heating.
With a capacitor-input filter and light load, DC climbs near the peak, about 1.41 U peak minus ripple, some 311 volt at 220 volt; under heavy load the cap discharges more so DC falls to about 1.2 U peak with larger ripple. The simple 0.637 rule no longer applies. Size the cap by C at least I delta t over delta U, with delta t 10 millisecond for full-wave, and rate the bridge at two to three times the 311 volt peak.
| Case | Average | RMS |
|---|---|---|
| Half | 0.318 Up | 0.5 Up |
| Full | 0.637 Up | 0.707 Up |
| Cap light | about 1.41 Up | with ripple |
| Cap heavy | about 1.2 Up | big ripple |
| Ripple C | C>=I dt/dU | dt=10 ms |
| Bridge | 2-3x peak | 600 V at 220 |
First ask whether there is filtering and how heavy the load is. Use 0.318 or 0.637 without a cap, and 1.2 to 1.4 U peak with one, then verify. Rate caps and bridges by the peak with margin; the average formula will undersize and burst them.
The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Rectifiers follow GB/T 4011 and supplies GB/T 14714. Always check the device datasheet and the product design file for ratings and derating.
Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.