Rectified voltage: RMS versus average at a glance

After rectifying AC to DC the link between RMS and average gets complicated. This page covers half-wave and full-wave rectification with and without capacitor filter, with a quick table for the bench.

1. How it works

Without filtering, half-wave rectified average is U peak over pi, about 0.318 U peak, with RMS half the peak; full-wave average is two U peak over pi, about 0.637, with RMS U peak over root two because power is unchanged. So full-wave average is twice half-wave, and the average is the useful DC while RMS drives heating.

2. Practice and pitfalls

With a capacitor-input filter and light load, DC climbs near the peak, about 1.41 U peak minus ripple, some 311 volt at 220 volt; under heavy load the cap discharges more so DC falls to about 1.2 U peak with larger ripple. The simple 0.637 rule no longer applies. Size the cap by C at least I delta t over delta U, with delta t 10 millisecond for full-wave, and rate the bridge at two to three times the 311 volt peak.

3. Rectified voltage table

CaseAverageRMS
Half0.318 Up0.5 Up
Full0.637 Up0.707 Up
Cap lightabout 1.41 Upwith ripple
Cap heavyabout 1.2 Upbig ripple
Ripple CC>=I dt/dUdt=10 ms
Bridge2-3x peak600 V at 220

4. Notes

First ask whether there is filtering and how heavy the load is. Use 0.318 or 0.637 without a cap, and 1.2 to 1.4 U peak with one, then verify. Rate caps and bridges by the peak with margin; the average formula will undersize and burst them.

5. References

The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Rectifiers follow GB/T 4011 and supplies GB/T 14714. Always check the device datasheet and the product design file for ratings and derating.

6. Cautions

⚠️ Three common pitfalls:
① Using the no-filter formula sizes the cap too small and ripple bursts it
② Rating the bridge by RMS lets the 311 V peak exceed and break it
③ Treating heavy load as light over-estimates DC and starves the load