Four boundary conditions: linear I-V, stable temperature, within ratings, frequency-insensitive.
Lamp filaments curve upward as they heat; varistors switch by design - non-linearity is a feature for protection parts.
Quick test: measure two (U,I) pairs; a straight line through the origin means Ohm's law applies.
| Device | Linear region | Out of bounds | Method |
|---|---|---|---|
| Film resistor | Within rating | Overload burn | Ohm's law |
| Lamp | Hot only | 10× cold inrush | Operating point |
| NTC | Small current | Self-heating | R-T table |
| Diode | Below ~0.5V | Exponential on | 0.7V model |
| Varistor | Standby high-Z | Conducts on surge | Energy rating |
| Gas discharge tube | Standby | Arc mode | Impulse rating |
Apply the points above to Non; the figures are typical engineering values, so confirm them against the device datasheet and the actual design before release.
The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Per IEC 60115, GB 50057, GB/T 18802 and the corresponding IEC documents. Ratings and derating follow the device datasheet and the product design file. Always check the device datasheet and the product design file for ratings and derating.
Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.