Non-linear I-V curves and the boundary of Ohm's law

Four boundary conditions: linear I-V, stable temperature, within ratings, frequency-insensitive.

1. How it works

Lamp filaments curve upward as they heat; varistors switch by design - non-linearity is a feature for protection parts.

2. Practice and pitfalls

Quick test: measure two (U,I) pairs; a straight line through the origin means Ohm's law applies.

3. Linearity boundary table

DeviceLinear regionOut of boundsMethod
Film resistorWithin ratingOverload burnOhm's law
LampHot only10× cold inrushOperating point
NTCSmall currentSelf-heatingR-T table
DiodeBelow ~0.5VExponential on0.7V model
VaristorStandby high-ZConducts on surgeEnergy rating
Gas discharge tubeStandbyArc modeImpulse rating

4. Notes

Apply the points above to Non; the figures are typical engineering values, so confirm them against the device datasheet and the actual design before release.

5. References

The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Per IEC 60115, GB 50057, GB/T 18802 and the corresponding IEC documents. Ratings and derating follow the device datasheet and the product design file. Always check the device datasheet and the product design file for ratings and derating.

6. Cautions

⚠️ Three common pitfalls:
① Applying Ohm's law outside the linear region
② Testing NTCs with large current
③ Sizing protectors by resistance logic

Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.