Upper and lower switch coordination in a three-phase inverter bridge

A three-phase inverter bridge fails at power on when the high and low switches of each leg are not coordinated, usually from missing dead time or a weak bootstrap. This page covers the six-switch arrangement, the timing values and the practical bring-up order.

1. How it works

The bridge is three half bridges in parallel, each leg stringing a high and a low switch between the DC bus rails and feeding the motor winding from the midpoint. The two switches of one leg must never conduct together, or the bus shorts through them and hundreds of amperes destroy the stage instantly. Phases U, V and W run 120 electrical degrees apart, and the high-side source floats at the midpoint, so its drive needs a bootstrap or an isolated supply, per GB/T 4728.

2. Numbers and practice

Set dead time from the turn-off time with margin: 3 to 5µs for IGBT legs, 0.2 to 1µs for MOS bridges, with 0.5µs a safe start. Fit a 0.47 to 1µF low-leakage X7R bootstrap capacitor and a fast recovery diode such as UF4007. The high-side gate needs a steady 10 to 12V referenced to its own floating source, and above a 10kHz carrier you must verify the bootstrap charge budget each cycle, gate charge plus quiescent draw with a doubled margin.

3. Pitfalls and fixes

Bring up at a low bus voltage such as 24V with a dummy load, and scope both gate waveforms of one leg to confirm no overlap before raising voltage. Classic traps: software dead time that ignores interrupt jitter, slow 1N4007 bootstrap diodes that starve the high side at frequency, and thin bus decoupling that lets switching spikes exceed ratings. Match upper and lower switches from one batch to keep the legs balanced.

4. Three-phase bridge coordination checklist

ItemRecommendedFailure if wrong
Dead time0.5 to 1µsshoot-through blows the bridge
Bootstrap cap0.47 to 1µF X7Rhigh side underdriven
Bootstrap diodeUF4007 fastslow diode starves at frequency
High-side drive10 to 12V floatinghalf on and hot
Carrier frequency5 to 20kHzbootstrap cannot recharge
Bring-up bus24V firstfault at full voltage

5. Notes

Leg coordination applies to inverters, servo drives and welding sources. Prove dead time at low bus voltage, keep one bootstrap per phase, and always re-check the gate waveforms after replacing switches.

6. References

The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Three-phase bridge and drive per GB/T 4728; equipment safety IEC 60204-1. Always check the device datasheet and the product design file for ratings and derating.

7. Cautions

⚠️ Three common pitfalls:
① Dead time lost to software jitter: the leg conducts through and the bus shorts instantly
② Slow bootstrap diode: the high side starves at frequency and burns half on
③ First power-up at full bus voltage: unverified timing shorts the whole bridge

Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.