Reversing a single-phase motor and its wiring

To reverse a single-phase motor you swap a wire, but swap the wrong one and you blow the capacitor. This page shows which winding to reverse for start and run types and how to wire the switch or contactors.

1. How it works

In a capacitor-start motor the main winding stays fixed to the supply; reverse the auxiliary winding, including its start capacitor, by swapping its two ends so the field direction flips and the rotor turns the other way. Never swap the main winding. A forward-reverse switch or relay swaps the auxiliary ends; the centrifugal switch still acts on speed and is unaffected.

2. Practice and pitfalls

In a capacitor-run motor the auxiliary winding is permanently capacitive, so reverse it or the capacitor connection to flip the phase relation with the main winding. Some motors bring out three or four terminals; follow the diagram exactly, because wild connection can short the capacitor. Use a three-position reversible switch with mechanical interlock for small power, or two interlocked contactors for frequent duty; never let both directions close at once. Jog to confirm direction before load, and for frequent reversal a single-phase VFD is smoother and arc-free.

3. Reversing schemes and wiring of single-phase motors

TypeWhat to swapMethodCaution
Capacitor startAuxiliary windingSwap its two endsMain winding untouched
Capacitor runAuxiliary incl. capSwitch tapsFollow diagram
Drum switchThree positionsMechanical interlockNever short
ContactorsTwo pathsElectrical interlockPrevent short
VFDPhase orderSmoothNo arcing

4. Notes

Reverse a single-phase motor by swapping the ends of the auxiliary winding including its capacitor while the main winding stays put; capacitor-run motors follow the terminal diagram for tap switching. Use a drum switch or mutually interlocked contactors, and never let forward and reverse close together. Jog first to confirm direction; for frequent reversal a single-phase VFD is the robust choice.

5. References

The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Low-voltage switchgear: GB/T 14048 / IEC 60947; single-phase motors: GB/T 12350. Always check the device datasheet and the product design file for ratings and derating.

6. Cautions

⚠️ Three common pitfalls:
① Swapping the main winding to reverse: it does nothing and may burn the winding
② Wiring terminals from memory shorts the capacitor, which bursts violently
③ Contactors without interlock closing forward and reverse together create a dead short

Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.