PWM turned DC speed control from resistor heat into efficient chopping, and the duty cycle is the throttle. Frequency choice, ripple control and the H-bridge implementation decide whether the drive runs clean or cooks itself.
A switch chops the DC supply into pulses applied to the armature, with average voltage equal to duty cycle times supply. The motor inductance smooths the current into DC with small ripple, and speed follows the average voltage: still voltage control at heart, but the losses moved from resistor heat into switching losses, reaching 95 percent efficiency and stepless response down to low speed. Compared with series-resistance control nothing burns and the low-speed characteristic stays stiff, which is why PWM owns everything from model cars to industrial drives.
Frequency is a trade: below 1kHz the motor whines and ripple grows, above 16 to 20kHz ripple shrinks but switching losses climb, with industrial drives typically at 4 to 20kHz. Ripple amplitude runs about U·D·(1−D)/(L·f), so more inductance or higher frequency calms it, protecting iron losses and, on brushed machines, the commutation. For bidirectional service an H-bridge gives forward, reverse and dynamic braking with 0.5 to 2 microseconds of dead time against shoot-through. Layout decides reliability: bus capacitor hugging the bridge for a low-inductance loop, short gate runs, and single-point joining of power and control grounds.
| Parameter | Recommended range | If too low | If too high |
|---|---|---|---|
| switching frequency | 4~20kHz (16k+ small motors) | audible whine, big ripple | switching loss and heat |
| dead time | 0.5~2µs | shoot-through destroys devices | duty cycle lost |
| duty range | 5%~95% | weak low-speed start | poor high-end resolution |
| bus capacitor | sized to ripple, hugging bridge | pumping spikes break devices | cost and volume wasted |
| device current margin | 1.5x stall current | trips at every start | money wasted |
| series reactor | as ripple demands | ripple, iron loss, sparks | voltage drop and bulk |
Commission at low voltage unloaded, then measure current under load, then full-load temperature and efficiency. Scope the switching nodes with a differential probe; clipping a standard ground lead to a bridge leg shorts the bus and kills the probe.
The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: See GB/T 3886.1 for semiconductor converters in DC adjustable-speed drives; electrical safety per GB/T 5226.1 (IEC 60204-1). Always check the device datasheet and the product design file for ratings and derating.
Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.